V-Bank Transition System (VTS)
PureAir Filtration’s V-Bank Transition System (VTS) system is a complete self contained, vertical airflow unit.
This deep bed system provides continuous high efficiency air purification for contaminated air streams ranging in volume from 6000 to 40,000 CFM while maintaining a compact, flexible design. The PureAir VTS systems come in either blow-through or draw-through configurations. As with all PureAir systems, the PureAir VTS is completely customizable.

LOCATION: Cobb County, Georgia
EQUIPMENT/MEDIA USED: V-Bank Transition System (VTS) filled with Sulphasorb XL™ and CPS Blend adsorbent media
PROBLEM: A high volume of VOCs, H2S and other gases being released from the Biosolids Transfer Station are causing complaints from neighbors.
SOLUTION: PureAir installed a VTS filled with both Sulphasorb XL™ and CPS Blend adsorbent media to treat 40,000 CFM of malodorous air. Odorless air, happy staff, and a cease in complaints from neighbors is the result.
LOCATION: Saudi Arabia, Khafji
EQUIPMENT/MEDIA USED: Side Access Housing (SAH), V-Bank Transition System (VTS) and Sulphasorb Fe™ and PureAir 12 adsorbent media
PROBLEM: Extremely high levels of H2S are corroding electronics and compromising the safety of employees.
SOLUTION: PureAir installed six SAH units to protect mission critical electronics and five VTS filled with PureAir 12 and Sulphasorb Fe™ adsorbent media. Since our systems and media were installed, H2S levels are reported to be undetectable.